High-quality Perkins diesel generator 150kVA
A-P150S
Standby Power: 150/120 (KVA/KW)
Prime Power: 138/110 (KVA/KW)
Engine Model:1106A-70TG1
Engine Speed: 1500 RPM
Alternator Model: UCI 274 E
Starting System: Electric
Cylinder: 6 Cylinder in line
Fuel Type: Diesel
Dimension:3100X 1080 X 1600(L x W x H)
Weight: 1850kg
minimum order: 1 unit
Supply Ability: 500 units / Month
Country of Origin: China
Stock Time: 30-35 Days
Prime Power: 138/110 (KVA/KW)
Engine Model:1106A-70TG1
Engine Speed: 1500 RPM
Alternator Model: UCI 274 E
Starting System: Electric
Cylinder: 6 Cylinder in line
Fuel Type: Diesel
Dimension:3100X 1080 X 1600(L x W x H)
Weight: 1850kg
minimum order: 1 unit
Supply Ability: 500 units / Month
Country of Origin: China
Stock Time: 30-35 Days
Quantity
Product Description
This 110kW (138kVA) Perkins diesel generator (Model A-P150) pairs a genuine Perkins engine with a Stamford alternator, delivering stable 400/230V three-phase power with efficient fuel consumption. Fitted with a Deepsea controller for comprehensive protection, it is ideal for industrial and mission-critical backup applications.
Generator Set Specification:
| Model | A-P150S | |
| Max. Power | kVA | 150 |
| kW | 120 | |
| Rate Power | kVA | 138 |
| kW | 110 | |
| Frequency | Hz | 50 |
| Rate Voltage | V | 400/230 |
| Rate Current | A | 198.5 |
| Fuel Tank Capacity | L | 250 |
| Dimension For Open-type Genset | mm | 2450 X 800 X 1400 |
| Weight For Open-type Genset | kg | 1390 |
| Dimension For Soundproof Genset | mm | 3100X 1080 X 1600 |
| Weight For Soundproof Generator | kg | 1850 |
| Noise Level for Soundproof Generator at 7M | dBA | 75 |
| Battery for Starting | One of Free Maintenance Battery | |
Engine Specification:
| Engine Manufacturer | Perkins Engines Company Limited | |
| Engine Brand | Perkins | |
| Engine Model | 1106A-70TG1 | |
| No. of Cylinder | 6 Cylinder in line | |
| Aspiration | Turbocharged | |
| Governor | Electric | |
| Engine Max. Output Power | kW | 136.9 |
| Displacement | L | 7.0 |
| Compression Ratio | 18.2 : 1 | |
| Starting Voltage | V | 12 |
| Bore | mm | 105 |
| Stroke | mm | 135 |
| Lubrication Oil Capacity | L | 16.5 |
| Intake Air Flow | M3/Min | 9.4 |
| Fuel Consumption at 100% Load | L/H | 30.2 |
Alternator Specification:
| Alternator Manufacturer | Cummins Generator Technologies | |
| Alternator Model | UCI 274 E | |
| Alternator Brand | Stamford | |
| Rate Output | kVA | 140 |
| Frequency | Hz | 50Hz |
| Altitude | M | ≤1000 |
| Insulation | Class H | |
| Phase | 3 Phase | |
| Working Temperature without power decrease | ≤40℃ | |
| Working Altitude without power decrease | ≤1000m | |
| Automatic Voltage Regulation | SX440 | |
| Protection Grade | IP23 | |
| Alternator for optional | Leroy Somer, Marathon, Mecc Alte and Hosem Brushless alternator for optional | |
Control Panel Specification:
| Controller Brand | Deepsea | |
| Controller Model | DSE7320 | |
| Breaker Brand | Delixi | |
| Breaker Capacity (A) | 250 | |
| Battery Charger | Smartgen Model BAC06A | |
| Emergency Stop Button | Supply | |
| Automatic Mains Fail (AMF) | Supply | |
| Fuel Level | Supply | |
| Automatic Transfer Switch | ATS as optional part | |
| The control panel supply the full protection with alarm and shutdown of the diesel generator include Start-up fault (generator set shutdown), High coolant temperature (alarm and generator set shutdown), Low oil pressure (alarm and generator set shutdown), Low fuel level (alarm), Low cooling fluid level alarm (as optional), Overload (alarm and generator set shutdown), Battery voltage high (alarm). | ||
| Optional controller: Each model of Deepsea, Smartgen, ComAp brand controller. | ||
FQA:
Q1: What is the standby and prime power of the 150kVA Perkins diesel generator?
A: This 150kVA Perkins diesel generator has a standby power of 150kVA/120kW and a prime power of 138kVA/110kW, making it ideal for industrial standby power, commercial backup power, and construction site power supply.
Q2: What engine is used in the 150kVA Perkins genset? Is it reliable?
A: The 150kVA Perkins diesel genset is equipped with the original Perkins 1106A-70TG1 6-cylinder in-line turbocharged engine, featuring mature craftsmanship, high durability, and low fuel consumption (30.2L/H at 100% load), ensuring long-term stable operation for industrial use.
Q3: How noisy is the 150kVA soundproof Perkins diesel generator?
A: The soundproof 150kVA Perkins generator has a 75dBA noise level at 7 meters, making it perfect for noise-sensitive areas like residential buildings and hospitals.
Q4: What optional configurations are available for Perkins diesel generators?
A4: Optional configurations include ATS (automatic transfer switch) receptacle, remote control system, virtual load cabinet, stainless galvanized zinc plates with strong corrosion resistance, water jacket preheater, oil heater, double air cleaner, etc., which can meet the diverse customization needs of customers.
Q5: Can we customize the product?
A5: We have a very experienced technical team, we can customize any product according to your requirements.