Two 800kVA Cummins Generator for Hospital in The Philippines
author: Jack Zheng
2020-03-29
Specification:
| Model | A-C853H | |
| Standby Power | kVA | 853 |
| kW | 682 | |
| Prime Power | kVA | 775 |
| kW | 620 | |
| Frequency | Hz | 60 |
| Output Voltage | V | 240 |
| Oil Consumption | L/H | 0.500640861 |
| Dimension For Open-type | mm | 4243 X 1820 X 2323 |
| Weight For Open-type | kg | 6058 X 2438 X 2591 |
| Dimension For Soundproof | mm | 85 |
| Weight For Soundprof | kg | 3832 |
| Engine Model | KT38-G | |
| No.of Cylinder | 12 Cylinder V Type | |
| Bore | mm | 159 |
| Stroke | mm | 159 |
| Displacement | L | 37.8 |
| Cooling Fan Air Flow | m3/min | 1825 |
| Compress Air Flow | m3/min | 55.2 |
| Exhaust Gas Flow | m3/min | 158.6 |
| Exhaust Gas Temperature | ℃ | 552 |
| Lubrication Oil Capacity | L | 135 |
| Cooling Water Capacity | L | 194 |
| Starting Voltage | V | 24 |
| Engine Max.Output Power | kW | 747 |
| Alternator Model | HCI 544 F-S | |
| Alternator Brand | Stamford | |
| Rate Output | kVA | 775 |
| Frequency | Hz | 60 |
| Altitude | M | ≤1000 |
| Insulation | Class H | |
| Protection Grade | IP23 | |
| Alternator for choice | We also have Leroy Somer, Marathon, Mecc Alte and Chinese brand Brushless alternator for your choice. | |
| Control Panel Model | AF500 | |
| Controller | Deepsea Brand Model DSE7320 | |
| Function of control panel | Automatic genset start/stop | |
| Automatic battery charger | ||
| Emergency stop | ||
| AMF (Automatic Mains Fault) | ||
| Remote control | ||
| Micro-processor based design | ||
| LED alarm indication and Sound alarm | ||
| Display of the controller | Generator voltage: Uab, Ubc, Uca | |
| Generator current: Ua, Ub, Uc | ||
| Generator temp.: ℃/℉ both display | ||
| Generator frequency: Hz | ||
| Generator power: kW, kVA, kWh, kVAr, kVArh, kVAh | ||
| Generator starts count: 999999 times (Max) | ||
| Generator pressure: kPa/Psi/Bar both display | ||
| Charging Voltage: V | ||
| Battery Voltage: V DC | ||
| Protection of Diesel Generator | Over / Under Speed Alarm and Shutdown | |
| Start / Stop Failure Alarm | ||
| Over Current Alarm and Shutdown | ||
| Under / Over Generator Voltage Alarm and Shutdown | ||
| Low Oil Pressure Alarm and Shutdown | ||
| High Engine Temperature Alarm and Shutdown | ||
| Over Load Alarm and Shutdown | ||
| Low and High Battery Voltage Alarm | ||
| Lose of Speed Signal Alarm and Shutdown | ||
| Charge Fail Alarm | ||